LIN-SEAL® WHITE
CURING AND ANTI-SPALLING COMPOUND
DESCRIPTION
LIN-SEAL WHITE curing and anti-spalling
compound is a true water-based, white-pigmented,
high solids emulsion of boiled linseed
oil. When properly applied, it provides a nearly
impermeable seal that optimizes water retention.
The white pigments reflect the heat-producing
rays of the sun to keep the concrete surface cooler
and prevent excessive heat buildup.
LIN-SEAL WHITE curing and anti-spalling
compound is a true water-based product. LIN-SEAL
WHITE meets maximum VOC content
limits of 350 g/L for Concrete Curing Compounds
as required by the U.S. EPA Architectural
Coatings Rule.
USES
LIN-SEAL WHITE curing and anti-spalling
compound is ideal for preventing the spalling and
scaling of concrete surfaces. Use on bridge decks,
parking garage decks, ramps and/or any concrete
surface exposed to water, de-icing salts or other
deleterious materials. The product increases the
durability of concrete to prolong its service life.
| SPECIFICATIONS |
- ASTM C 309, Type 2, Class A & B*
- AASHTO M 148, Type 2, Class A & B*
- Numerous state DOT specifications
*With exemption for drying
time.
|
| TECHNICAL DATA (Typical) |
Color:
Solids, wt. %:
Weight per Gal., lb./gal:
Flash Point, °F (C): |
White Liquid
52.0
8.5
>212 (100) |
| FEATURES/BENEFITS |
- When properly applied, provides a nearly
impermeable film which optimizes water
retention.
- Protects by reflecting the sun’s rays to keep the
concrete surface cooler and prevent excessive
heat buildup, which can cause thermal
cracking.
- Furnished as a ready-to-use, true water-based
compound.
- Produces hard, dense concrete ... minimizes
hair-checking, thermal cracking, dusting and
other defects.
- Prevents scaling and spalling.
- Offers a compressive strength significantly
greater then improperly or uncured concrete.
- Increases tensile strength for greater resistance
to cracking and surface crazing.
- Improves abrasion resistance and minimizes
corrosive action of salts and chemicals ...
minimizes shrinkage.
- Applies quickly and easily with conventional
commercial spray equipment.
- VOC-compliant ... VOC content is <50 g/L.
|
PACKAGING
5 Gallon (18.93 Liter) Pails
55 Gallon (208.20 Liter) Drums
APPLICATION
Preparation
Application equipment must be
clean and free of any previously used
products/liquids.
Mixing … Any settling or separation in the
container must be re-dispersed with gentle
agitation prior to use. CAUTION: DO NOT MIX
EXCESSIVELY.
Application Method ... Spray on in one even
coat with hand or power spray equipment as soon
as surface water disappears from the horizontal
concrete surface. On vertical surfaces, spray on
promptly after the forms are removed. Use of a
Chapin 1949 sprayer with a 5797 spray nozzle (or
equivalent) is recommended. A 5797 nozzle will
produce a desired flow of 1/2 gallon (1.89 L) per
minute under 40 psi (.276 MPa) of pressure.
Proper application is the responsibility of the
user. Field visits by W. R. MEADOWS
personnel or their representatives are for the
purpose of making technical recommendations
only and are not to supervise or provide quality
control on the jobsite.
Coverage … Approximately 200 ft.²/gal. (4.91
m²/L). Coverage may vary due to porosity and
condition of the concrete.
Cleanup … Prior to drying, application
equipment can be easily cleaned up with soap and
water. Once dried, use mineral spirits or other
suitable solvent.
NOTE: Materials soaked with linseed oil (rags,
absorbents, etc.) may spontaneously catch on
fire if improperly discarded. Immediately after
use, all materials coming in contact with this
product should be placed in a water-filled
container. This container should then be
covered and sealed closed.
PRECAUTIONS
KEEP FROM FREEZING. Do not apply when
the temperature of the concrete is less than 40º F
(4º C). DO NOT MIX OR DILUTE WITH ANY
OTHER LIQUIDS OR PRODUCTS. Do not use
on surfaces that are later to be painted, tiled,
hardened, sealed or treated in any manner. Do not
use on patios, sidewalks or other areas where
there is no wheel traffic to abrade the white film
surface. Not recommended for use on residential
driveways.
HEALTH HAZARDS
Direct contact may result in mild irritation. Refer
to Material
Safety Data Sheet for complete health
and safety information.
SHELF LIFE
One year in original, unopened container.
This material last updated January 2008.