Product Data, W. R. MEADOWS
07 27 13
No. 718
Click here for:

AIR-SHIELD

SELF-ADHERING AIR/VAPOR AND LIQUID MOISTURE BARRIER

DESCRIPTION
AIR-SHIELD self-adhering air/vapor and liquid moisture barrier is part of a total W. R. MEADOWS system to complete the building envelope.  It is a roll-type product that is nominally 40 mils thick. The membrane's controlled thickness is fabricated from cross-laminated polyethylene bonded to specially modified asphalt.

This unique, self-adhesive membrane, protected by a special release paper, is strong and durable. It remains flexible when surface mounted and will adhere to most primed surfaces at minimum temperatures of 40° F (4° C).   The membrane provides excellent protection as a tough barrier that won't shrink, sag, dry out, crack or rot. It offers excellent resistance to punctures during installation. The self-healing characteristics of AIR-SHIELD facilitate recovery if minimal damage is sustained under normal use applications, i.e. when penetrated with self-tapping screws or nails.

USES
AIR-SHIELD self-adhering air/vapor and liquid moisture barrier is designed for a variety of uses.

Primary applications include cavity wall and masonry wall construction. AIR-SHIELD works equally well as an air and/or vapor barrier on precast concrete, cast-in-place concrete, masonry (concrete block), interior and exterior gypsum board, styrofoam, primed steel, aluminum mill finish, anodized aluminum, primed galvanized metal, drywall and plywood.

FEATURES/BENEFITS
  • LOW PERMEABILITY - prevents the transmission of air and inhibits moisture vapor through porous building materials.
  • Provides a complete above-grade air, vapor and water barrier on a variety of construction materials.
  • Controlled thickness membrane is ideal for air barrier applications.
  • Cross-laminated polyethylene film has excellent tensile strength, elongation and tear resistance.
  • Modified membrane is flexible at low temperatures.
  • Excellent adhesion to prepared substrates of precast concrete, cast-in-place concrete, masonry (concrete block), interior and exterior gypsum board, styrofoam, primed steel, aluminum mill finish, anodized aluminum, primed galvanized metal, drywall and plywood.
  • Self-healing characteristics facilitate recovery if minimal damage is sustained under normal use applications.
  • No flame required.
  • Low temperature version also available – can be applied at temperatures between 20˚ F (-7˚ C) and 60° F (16° C).
  • AIR-SHIELD XLT can be applied at minimum temperatures of 0° F (-18° C).

PACKAGING
AIR-SHIELD is packaged in rolls of 38.5" (.97 m) x 75' (22.86 m).  AIR-SHIELD can also be cut to desired width. 

Optional sizes include:
4" x 75', 6" x 75', 9" x 75', 12" x 75', 16" x 75'
18" x 75', 20" x 75' and 24" x 75'.

STORAGE
AIR-SHIELD should be stored palletized and protected from rain and/or physical damage. Do not store at temperatures above 90º F (32.2º C) for extended periods of time. Do not leave membrane exposed to direct sunlight. Do not double-deck pallets.  Store away from sparks or flames. Outdoors, store AIR-SHIELD on pallets and completely cover.

SPECIFICATIONS
  • Exceeds the requirements of the Massachusetts Commercial Energy Code for Building Envelope Systems.
  • Meets CAN/CGSB-51-33, Type I Water Vapor Permeance Requirements.
  • 2005 National Building Code of Canada
  • ABAA Section 07261 Self-Adhering Air and Vapor Barrier Specification

MAINTAIN ENERGY EFFICIENCY
AIR-SHIELD provides an effective barrier to air exfiltration and infiltration, reducing condensation within the wall assembly and increasing efficiency of a building’s mechanical system.  Wet insulating materials lose much of their R-factor performance characteristics, reducing the energy efficiency of the structure. W. R. MEADOWS thermal and moisture protection products play a key role in maintaining the structure’s energy efficiency and aiding in the integrity of other structural systems, such as insulation.

TECHNICAL DATA
Test Results
Color: White
Thickness: 40 mils (1mm)
Pliability @ -25° F (-32° C) No effect
Tensile Strength Film
ASTM D 412 modified (MD):
ASTM D 882 (MD): lb./in.
4,000 psi (27.6 Mpa)
23.5 lb./in. (4.1 N/mm)
Elongation Film:
ASTM D 412 modified (MD,%):
ASTM D 882, (MD,%):
400 (Typical)
400 Min.
Puncture Resistance:
ASTM E 154
40 lbf (178 N) Min.
Water Vapor Permeance (free film)
ASTM E-96, Procedure B
0.035 Perms
Water Absorption (% by weight)
ASTM D 1970
ASTM D 570-81
0.25 Max
0.1 Max
Application Temperature: 40° F (4° C) Min.
Low Temperature Flexibility @ -22° F (-30° C)
(CGSB 37-gp-56m)
PASS
Service Temperature -40° F to 158° F
Lap Peel Strength @ 39° F (4° C)
(ASTM D 903, 180 Bend)
10 lbf/in width
(1.75 N/mm)

** Air leakage tested per ASTM E 283
 

Pressure

Air Leakage
(National Building Code of Canada Requirement)

Results for
AIR-SHIELD

Air Leakage
(National Building Code of Canada Requirement)

Results for
AIR-SHIELD

Pa

lbs./ft²

L/S/M²
 

cfm/ft²
 

75

1.57

0.02

Meets

0.004

Meets

** Air leakage tested per ASTM E 2178

Pressure

Air Leakage
(National Building Code of Canada Requirement)

Results for
AIR-SHIELD

Air Leakage
(National Building Code of Canada Requirement)

Results for
AIR-SHIELD

Pa

lbs./ft²

L/S/M²
 

cfm/ft²
 

75

1.57

0.02

Less than 0.02

0.004

Less than 0.004

**Independent tests available upon request.

APPLICATION
Surface Preparation
…All surfaces to be protected must be clean, dry, frost-free and smooth. Remove any sharp protrusions and repair all defects. All surfaces to receive AIR-SHIELD must be clean of oil, dust and excess mortar.  Strike masonry joints flush.  Concrete surfaces must be smooth and without large voids, spalled areas or sharp protrusions.  Concrete must be cured a minimum of 14 days and must be dry before AIR-SHIELD is applied.  Where curing compounds are used, they must be clear resin-based, without oil, wax or pigments.

Priming…All surfaces to which AIR-SHIELD is to be applied must be primed with MEL-PRIME™ or MEL-PRIME W/B primer from W. R. MEADOWS. Primer may be applied to an area that is to be covered the same day. Uncovered areas must be re-primed the next day. See primer container for complete application directions, drying information and precautions.

Application Method…AIR-SHIELD self-adhesive air/vapor and liquid moisture barrier can be applied at minimum temperatures of 40º F (4º C). Apply membrane to primed surface by removing release paper and rolling membrane firmly into place. Remove release paper only as membrane is being applied.  Ensure membrane is fully adhered and remove all wrinkles and/or fish mouths. Cut AIR-SHIELD membrane with a utility knife to detail around protrusions and masonry reinforcing. Seal all end laps and protrusions with POINTING MASTIC from W. R. MEADOWS.  Overlap subsequent courses of membrane a minimum of 2”. Vertical terminations of AIR-SHIELD should either be tied into the wall system or mechanically fastened with TERMINATION BAR from W. R. MEADOWS.  AIR-SHIELD is not designed for permanent exposure. Good construction practices call for application of insulation as soon as possible to protect the air barrier. 

Clean Up…Tools, etc. can be cleaned with mineral spirits, paint thinner or aromatic solvent.

COVERAGE
Coverage is approximately 240 ft² (22.3 m²). Net coverage when lapped 2” is 228 ft² (21.1 m²).

SAFETY & TOXICITY
No adverse effects expected with normal product use. Cotton work gloves and safety glasses are recommended. Refer to Material Safety Data Sheet for complete health and safety information.

BELOW-GRADE PROTECTION:
W. R. MEADOWS offers the following moisture and vaporproofing products, providing the specifying authority a single-source system for the entire building envelope: 

PREMOULDED MEMBRANE® VAPOR SEAL with PLASMATIC CORE® (PMPC) for horizontal vaporproofing applications. Refer to data sheet #711.

MEL-ROL® waterproofing membrane. Refer to data sheet #717.

MEL-DRAIN™ rolled matrix drainage system is designed to protect vaporproofing and waterproofing membranes in either horizontal or vertical applications.  Refer to data sheet #719.

ACCESSORIES
MEL-PRIME W/B…This water-base primer prepares concrete surfaces for AIR-SHIELD membrane application.  Product is ready to use and requires no additional mixing.  MEL-PRIME W/B emits no unpleasant odors and works with all waterproofing membranes from W. R. MEADOWS.  Can be applied easily by manual spraying or with a roller.  Product is VOC-compliant.  MEL-PRIME W/B is ideal for use at temperatures of 40° F (4° C) and above.
Coverage: 250 to 350 ft²/gal. (6.14 to 8.6 m²/L)
Packaging: 1 Gallon (3.79 L) Units, 4/Carton and 5 Gallon (18.93 L) Pails

MEL-PRIME…This solvent-base primer can be used at temperatures below 40° F (4° C) and above. Can be applied with a roller or brush.

Coverage: 250 to 300 ft²/gal. (6.14 to 7.4 m²/L)
Packaging: 1 Gallon (3.79 L) Cans and 5 Gallon (18.93 L) Pails

TERMINATION BAR…As an option, TERMINATION BAR may be used to mechanically fasten the membrane.
Packaging: (25) 10' pieces per 20 lb. carton (250 lineal feet)

POINTING MASTIC…Used for sealing exterior vertical and horizontal terminations, laps, around protrusions, and top edges of TERMINATION BAR.

Coverage: Approximately 200 lineal ft. (61 m) per gallon (3.79 L) when used as directed.
Packaging: 5 Gallon (18.93 Liter) Pails or 29 oz. (857.65 ml) cartridges, 12/Carton

This material last updated July 2007.