DESCRIPTION
AIR-SHIELD LMP is
a water-based air/liquid moisture barrier that cures to form a tough, seamless,
elastomeric membrane. AIR-SHIELD LMP exhibits excellent resistance to air leakage.
As a drainage plane, AIR-SHIELD LMP prohibits liquid water intrusion into the
substrate, if properly applied.
USE
AIR-SHIELD LMP has been specifically formulated to act as an air and liquid
moisture barrier, allowing vapor to pass through it while being impermeable
to liquid water. It may be applied to most common surfaces and integrated into
various wall systems. AIR-SHIELD LMP is suitable for both new construction and
retrofit applications.
SPECIFICATIONS
• Exceeds Air Barrier Association of America (ABAA) Section 07263 Liquid-Applied
Vapor Permeable Air Barrier System.
• Exceeds therequirements of the Massachusetts Commercial Energy Code
For Building Envelope Systems.
• 2005 National Building Code of Canada.
FEATURES/BENEFITS
|
SHELF LIFE
12 months in unopened container. Do not store in temperatures over 90° F
or below 40° F.
PACKAGING
5 Gallon (18.93 Liter) Pails
55 Gallon (208 Liter) Drums
| Solids Content Color |
58% (approx) Grey (Black – special order only) |
| Flexibility
@ -20° C (-26° C) (ASTM C836) Tensile Strength Elongation (ASTM D 412) Water Vapor Permeance (ASTM E-96, Procedure B) |
PASS 100 PSI 1200% 12 Perms |
| Service Temperature Nail Sealability (ASTM 1970) Application Temperature Storage Temperature |
Not to exceed 175°
F (80° C) Pass Above 40° F (4° C) 40° F to 90° F (4° C to 30° C) |
| Pressure | Air Leakage (ABAA requirement) |
Results for AIR-SHIELD LMP |
Air Leakage (ABAA requirement) |
Results for AIR-SHIELD LMP |
|
| Pa | lbs./ sq. ft. | L/sM² | L/sM² | cfm/sq. ft. | cfm/sq. ft. |
| 75 | 1.57 | 0.02 | Less than 0.02 | 0.004 | Less than 0.004 |
SURFACE PREPARATION
All surfaces must be clean (free of all coatings and curing compounds), structurally
sound and relatively smooth. AIR-SHIELD LMP can be applied to “green”
or damp concrete if there is no liquid water on the surface.
Exterior Sheathing Panels:
Prior to the application of AIR-SHIELD LMP, joints ¼” wide or greater
between exterior sheathing panels and between exterior sheathing panels and
dissimilar materials should be either pre-treated with a minimum 4" strip
of AIR-SHIELD membrane or filled with a compatible
sealant, such as an acrylic latex, prior to installation of AIR-SHIELD LMP.
Details and Protrusions:
Before application of AIR-SHIELD LMP, apply a 6” (152 mm) minimum wide
strip of AIR-SHIELD self-adhering air barrier where
joints between dissimilar building materials occur, i.e. details around doors
and windows, as well as protrusions. Architectural details are available online
at www.wrmeadows.com or by calling 1-800-342-5976.
Concrete Masonry Units:
Before applying AIR-SHIELD LMP to CMU surfaces, patch all cracks, protrusions,
small voids, offsets, details, irregularities and small deformities with MEADOW-PATCH®
5 or MEADOW-PATCH 20 from W.R. MEADOWS
at least two hours before application.
APPLICATION
AIR-SHIELD LMP may be applied by spraying or roller. (For recommendations on
spray equipment, consult W.R. MEADOWS technical staff.) AIR-SHIELD LMP may be
sprayed on at the minimum coverage rate of approximately 16-20 sq. ft./gal.
(90 mils, wet) (45 mils, dry). Frequently inspect surface area with a wet mil
gauge to ensure consistent thickness. Work material well into any fluted rib
forming indentations. Porous masonry block walls may require additional coats
to obtain desired thickness.
CURING & DRYING
Apply at air and surface temperatures of 40° F (4° C) or higher. Curing
times will be affected by relative humidity, temperature and airflow. The following
times are given for average conditions and standard thickness. Actual times
may differ, depending on specific conditions present on job at time of application.
It is recommended that AIR-SHIELD LMP be allowed to cure before application
of specified insulation.
Tack-free film: 2 hours
Full cure: 48 hours
| COVERAGE Application Rate Wet Film Thickness Cured Film Thickness |
16-20 sq. ft./gal. 90 mil (2.3 mm) 45 mil (1.15 mm) |
CLEAN-UP
Uncured AIR-SHIELD LMP cleans up easily while wet with water. Cured material
is best removed by Xylene (Xylol) or by mechanical means.
PRECAUTIONS
AND LIMITATIONS
Keep containers tightly sealed. KEEP FROM FREEZING.
Maximum UV exposure period for grey material is 6 months, unlimited for black.
Do not apply AIR-SHIELD LMP if rainfall is forecast or imminent within 12 hours.
Do not apply AIR-SHIELD LMP when air, material and surface temperatures are expected to fall below 32º F (0º C) within 24 hours of completed application.
HEALTH HAZARDS
Direct contact may result in mild irritation to the eyes and skin. Should adverse
effects occur, remove subject from area immediately. If irritation occurs and
persists, move victim from exposure source and treat symptomatically. Flush
affected areas with mild soap and water. Consult product Material
Safety Data Sheet (MSDS) for complete health and safety information.
TECHNICAL ASSISTANCE
Please contact W. R. MEADOWS for specific details and/or data not outlined in
this literature. Technical assistance, from design to product application, is
available upon request.
This material last updated March 2007.