| 07 10 00 |
|
Click
here for:
|

Description
PROTECTION COURSE from
W. R. MEADOWS is a multi-ply semi-rigid core composed of a mineral-fortified
asphalt core formed between two outside layers of asphalt-impregnated
reinforced mats, manufactured in accordance with ASTM D 6506.
When properly applied by personnel trained in good waterproofing
techniques, PROTECTION COURSE will absorb the impact of aggregate
shock and normal jobsite foot traffic. It also protects the membrane
waterproofing from penetration by sharp aggregate during backfilling
and later settlement.
PROTECTION COURSE is available in two types; PC-2, Standard Duty
and PC-3, Heavy Duty. Both types are economical and convenient
to use.
Uses
PROTECTION COURSE is used in between-slab construction,
such as plaza decks, roof terraces, promenade decks, pedestrian
concourses, tunnels, bathroom floors, showers, kitchens and mechanical
rooms, parking garage decks, planter boxes, reflective pools and
foundation walls.
PROTECTION COURSE from W. R. MEADOWS is compatible with most currently
popular dampproofing and waterproofing materials.
Features/Benefits
Packaging
4' x 8' (1.22m x 2.44m) panels
PHYSICAL PROPERTIES AND TEST
RESULTS
| TYPE 2 | TYPE 3 | |
|
Puncture Strength (Classes A & B) |
312 N (70 lbf) minimum | 365 N (82 lbf) minimum |
|
Thickness (Classes A & B) |
2.4 to 3.9mm (0.095 to 0.155 in.) |
5.6 to 7.1mm (0.220 to 0.280 in.) |
|
Water Absorption (Classes A & B) |
10% maximum | 10% maximum |
|
Asphalt, % by weight (Class A) |
65% minimum | 65% minimum |
|
Asphalt, % by weight (Class B) |
40% minimum | 40% minimum |
|
Resistance to Decay (Classes A & B) |
|
|
Application Tools
|
Trowel |
Roofer's Knife |
APPLICATION
NOTE: Prior to application,
consult the waterproofing manufacturer to determine whether the
polyethylene film facing on one side, or the asphalt-impregnated
reinforced mat on the other side of PROTECTION COURSE, is approved
as "compatible" to the specific waterproofing product
being protected.
PROTECTION COURSE is installed to form a continuous protective
layer over the membrane waterproofing. The sheets can be easily
cut with a roofer's knife for fitting at protrusions.
Surface Condition...The waterproofing membrane must be
free of sharp projections, dirt and dust. If water testing is
desired, it should be made prior to placing PROTECTION COURSE
Note: PROTECTION COURSE should be applied at the end of each day's
waterproofing to both horizontal and vertical surfaces.
Horizontal Surfaces...PROTECTION COURSE should be installed
over the waterproofing membrane as soon as permissible by the
membrane applicator or manufacturer. PROTECTION COURSE sheets
should be butted together and cut to fit all intersecting surfaces
and protrusions. If desired, joints may be covered with DETAIL
STRIP from W. R. MEADOWS or roofer's glass reinforced tape embedded
in hot asphalt as a secondary waterproofing system. (See Point
2 under Precautions.)
Vertical Surfaces...For dampproofed and/or waterproofed
vertical walls to receive backfill, the PROTECTION COURSE should
be butt-jointed and, if necessary, temporarily held in place while
backfilling.
Backfilling...Backfilling against vertical walls should
be done immediately using care and caution to avoid damaging the
waterproofing application. Backfill material should not be dropped
against the PROTECTION COURSE in such a manner that it could drag
the sheet down as the backfill drops. For horizontal applications,
the waterproofing and PROTECTION COURSE should be installed just
prior to the installation of the wearing surface.
PRECAUTIONS
1. Where PROTECTION COURSE
is adhered to waterproofing membrane, use the adhesive recommended
by the membrane manufacturer.
2. Where taped joints are desired with tape set in hot asphalt,
consult membrane manufacturer.
3. PROTECTION COURSE is shipped on pallets with the polyethylene
anti-stick sheet on the top or exposed side. PROTECTION COURSE
should be stored on pallets and placed on a level surface.
4. CAUTION...Do not apply PROTECTION COURSE over liquid applied
waterproofing membranes containing volatile solvents until all
of the solvent has evaporated. Consult membrane manufacturer for
specific application details prior to placing PROTECTION COURSE
from W. R. MEADOWS. Read and follow application information and
precautions. Refer to Material Safety
Data Sheet for complete health and safety information.
This material last updated March 2006.