Product Data Sheet
07 26 16 | #7100-312 |
PREMOULDED MEMBRANE® VAPOUR SEAL WITH PLASMATIC® CORE (PMPC)
Vapourproofing/Waterproofing Membrane
DESCRIPTION
PREMOULDED MEMBRANE VAPOR SEAL WITH PLASMATIC CORE (PMPC) is a patented seven-ply, weather-coated, permanently bonded, semi-flexible vapourproofing/waterproofing membrane. It is composed of an exclusive PLASMATIC CORE suspended mid-point between two layers of a homogeneous, bituminous material, and then sealed under heat and pressure between liners of asphalt-impregnated felt and a glass-mat liner. An asphalt weather coat is applied to the glass-mat liner and covered with a polyethylene anti-stick sheet.
PMPC provides a positive, easy-to-install, economical, true vapourproofing and waterproofing system for horizontal applications. Properly applied, it stops moisture migration in footings, concrete floors, and structural slabs. PREMOULDED MEMBRANE VAPOUR SEAL WITH PLASMATIC CORE is both waterproof and vapourproof.
It offers a perm rating of less than 0.002 perms, the lowest in the industry. The product is the ultimate when a true vapour seal is required. Among its unique features is the built-in protection course, which resists jobsite puncturing and the abrasive action of concrete placement. PMPC conforms to ASTM E1993. The exclusive PLASMATIC CORE adds flexibility, greater tensile strength, puncture resistance, and excellent handling characteristics, in addition to providing unequalled vapor barrier properties. PMPC helps meet and maintain the maximum slab moisture transfer rate of 1.45 kg/100 m²/24 hours (3 lb./1000 ft.²/24 hours), allowed by the flooring industry specifications.
Representative United States patent: USPN 7,179,761. (See also www.wrmeadows.com/patents for further patent/intellectual property information.)
USES
PMPC, when properly applied, is designed to stop moisture migration (liquid or vapour) in footings, concrete floor slabs, and structural slabs, which greatly reduces fungus, mildew, and mould. It is especially useful under slabs overlaid with wood, tile, epoxy, and urethane coatings, carpeting, and resilient or seamless flooring systems, since it helps prevent warping and buckling caused by moisture migration. PMPC also greatly reduces radon gas from entering the structure.
FEATURES/BENEFITS
- Offers a virtually impermeable vapourproofing system with a perm rating of less than 0.002 perms, the lowest in the industry.
- Provides excellent tensile strength and puncture resistance.
- Helps prevent warping, buckling, or delamination of subsequent flooring systems.
- Conforms to ASTM E 1993 specification.
- Greatly reduces fungus, mildew, and mold
- Greatly reduces radon gas from entering the structure.
- Helps meet and maintain the maximum slab moisture transfer rate of 1.45 kg/100 m²/24 hours (3 lb./1000 ft.²/24 hours), as allowed by the flooring industry specifications
SPECIFICATIONS
ASTM E 1993*
*Standard Specification for Bituminous Water Vapour Retarders used in Contact with Soil or Granular Fill under Concrete Slabs.
PACKAGING
WIDTH | LENGTH | WEIGHT |
Sheets 1.22 m (48″) | 2.44 m (8′) | 27.22 kg/9.29 m² (60 lbs./100 ft.²) |
STORAGE
Handling of PMPC is not critical because of its strength; however, it is advisable to stack the material on smooth ground or a wood platform in storage or at the excavation site. This will eliminate the possibility of the material deforming or warping.
TECHNICAL DATA
PRODUCT | WATER VAPOUR PERMEANCE RATING ASTM F1249 |
TENSILE STRENGTH ASTM E154, Section 9 |
PUNCTURE RESISTANCE ASTM E154 |
PERMS | N/MM (LB. FORCE/INCH) |
N (GRAMS) (LB. FORCE) |
|
PREMOULDED MEMBRANE VAPOR SEAL WITH PLASMATIC CORE | 0.0011 | 27.3 (156) |
663 (149) |
All technical data is typical information, but may vary due to testing methods, conditions, and operators.
APPLICATION
Estimating … When estimating the amount of PMPC required, figure the actual area plus 20% for overlap.
Cutting … PMPC can be cut with a roofer’s or linoleum knife, using a straight edge.
Bending … Normally to facilitate bending at a change in plane, such as at corners or footings, a 2×4 can be used to make the bend. In cold weather conditions, lightly heat the bending area and make the bend.
Pointing … Pointing with POINTING MASTIC from W. R. MEADOWS should be done wherever an edge is exposed to prevent water from traveling under a sheet.
Horizontal Installation (On- or Below-Grade) … By installing PMPC on the ground prior to placing the concrete floor, moisture will be prevented from coming through the floor slab. For sub-grade preparation prior to placement of PMPC, please see ACI 302.1R-04: Chapter 4, Section 4.1.4 – Base Material.
Above-Grade … In addition to the horizontal on- or below- grade application, PMPC can be placed on the intermediate structural slab, forming a “sandwich slab” installation. As a result, moisture is prevented from filtering downward from mechanical floors dedicated to heating and air conditioning equipment. This helps prevent damage to lower floor levels.
Application Method (Butt-Joint Method) … After the sheets are tightly butted together, remove the polyfilm from the joint area. After removal of the polyfilm, center PMPC TAPE from W. R. MEADOWS over the “butt joints” and roll down with pressure for a positive seal.
SEALING PROCEDURES
All protrusions through the concrete slab, such as sewer pipes, water pipes, and utility inlets, must have a positive seal between the protrusion and PMPC. Place a collar of PMPC at least 30.48 cm (12″) larger than the protrusion around the protrusion. Seal in place with PMPC TAPE and point around the protrusion with POINTING MASTIC.
ACCESSORIES
MEL-PRIME™ … Joints in concrete surfaces should be addressed with MEL-PRIME. MEL-PRIME is available in solvent– and water-based formulations. Packaging: 3.79 L (1 Gal.) Units, 18.9 L (5 Gal.) Pails
POINTING MASTIC … Used for sealing top horizontal terminations or slab protrusions. Packaging: 18.9 L (5 U.S. Gal.) Pails, 857.65 mL (29 oz.) Cartridges.
PMPC TAPE … A sturdy, self-adhering, reinforced tape of polymeric membrane that requires no additional adhesive. Tape is also made using the patented core material giving it superior WVT properties. Provides a simple, easy, and economical method of effectively sealing horizontal and vertical butt joints. Each strip is nominally 152.4 mm (6″) wide and 15.24 m (50′) long. Has quick-strip release paper for ease of handling and application. Packaging: 6 rolls per carton.
COVERAGE
ADHESIVE | JOINT METHOD | PER 1000 FT.² (92.9 m²) OF MEMBRANE (APPROX.) |
PMPC TAPE** | Butt-Joints/Overlap | 126.8 m (416 linear ft.) |
POINTING MASTIC*** | Detail Strip Edge Terminations |
161.0 m/L (2000 linear ft./gal.) |
**Water Vapour Perm Rating is 0.0011 | ||
***3.18 mm x 25.4 mm x 60.96 m (1/8″ x 1″ x 200 LF) |
PRECAUTIONS
PMPC does not negate the need for relief of hydrostatic heads. A complete drain tile system should be placed on the exterior of the footing and, in severe cases, on the interior of the footing as well. If applied to concrete surfaces, repair any spalled areas, fill all voids, and remove sharp protrusions.
Adhesive coverage ratios must be adjusted to compensate for surface irregularities and additional coats may be required to provide proper adhesion. For maximum concrete performance and durability, the floor slab concrete design should provide for the lowest possible slump and yet assure complete hydration of the concrete. Refer to Safety Data Sheet for complete health and safety information.
MASTERFORMAT NUMBER AND TITLE
07 26 16 – Below-Grade Vapour Retarders
2022-11