Product Data Sheet
07 13 00 |
DATA SHEET 5118-050 |
![]() |
PRECON®
Pre-Applied/Underslab Waterproofing Membrane
DESCRIPTION
PRECON is a composite sheet membrane comprised of a non-woven fabric, elastomeric membrane. The PLASMATIC CORE is a seven-layer matrix designed for toughness and provides the lowest water vapour transmission (WVT) rating on the market. Once concrete is poured against PRECON and the concrete cures, a mechanical bond forms that secures the concrete to the membrane.
USES
PRECON is used as a blindside membrane in vertical applications where access to the positive side is limited. Such applications include soldier pile and lagging, metal sheet piling, caissons, shotcrete and stabilized earth retention walls. The membrane can also be used for horizontal applications for underslab waterproofing and vapourproofing. Applications may include structures under continuous or intermittent hydrostatic pressure. In these situations, contact W. R. MEADOWS Technical Services for verification of installation requirements and applicable installation guidelines. Install PRECON in strict accordance with W. R. MEADOWS installation guidelines and details using all accessory products as specified or required.
FEATURES/BENEFITS
- Provides a waterproof seal between the membrane and poured concrete wall.
- Helps prevent moisture migration into the structure.
- Reduces methane and radon gas intrusion.
PACKAGING
1.2 m (4′) wide x 15.2 m (50′) long rolls, one roll per carton.
STORAGE AND HANDLING
Store membrane cartons on pallets and cover if left outside. Keep materials away from sparks and flames.
APPLICATION
Surface Preparation … Inspect all surfaces for any conditions detrimental to the proper completion of the work. Surfaces should be structurally sound. Remove debris or any other foreign material that could damage the membrane.
PRECON can be used with a caisson wall shoring system without the use of a drainage board, such as MEL-DRAIN™ from W. R. MEADOWS. W. R. MEADOWS recommends proper site drainage, but due to certain site conditions this sometimes cannot be done effectively. The decision to remove the drainage board should be at the discretion of the engineer. In situations where a drainage board is not applied, surface preparation is important. The substrate needs to be sound, solid, and smooth. Any gaps or voids >25 mm (1″) need to be grouted. When PRECON is used with MEL-DRAIN, the system can bridge gaps <50.8 mm (2″). However, gaps >50.8 mm (2″) will need to be grouted.
Application Method … PRECON may be applied at temperatures down to 5° C; however, in less than ideal environments or marginal conditions, consider the use of PRECON LOW TEMP below 16° C. PRECON LOW TEMP can be used in temperatures down to -4° C. MEL-PRIME™ from W. R. MEADOWS should be used to enhance the bond at the selvedge edge when conditions warrant it with both PRECON and PRECON LOW TEMP.
Prior to application of the blindside membrane, attach MEL-DRAIN™ rolled matrix drainage system from W. R. MEADOWS to lagging or soil retention system.
In vertical applications of PRECON, mechanically attach with fasteners every 305 mm (12″) across the top, within 13 mm (½”) of the top edge of the membrane. Install the membrane with the fabric side facing toward the concrete pour ( Application Video).
Remove release paper on 152.4 mm (6″) overlap. Apply membrane and roll press into place with a tile type roller.
End Laps … Overlap membrane 152.4 mm (6″). Prior to overlap, apply BEM, HYDRALASTIC 836 or MEL-ROL® LIQUID MEMBRANE (two-component) from W. R. MEADOWS in area to be lapped. Roll press membrane into BEM, HYDRALASTIC 836, or MEL-ROL LIQUID MEMBRANE. At terminations of membrane, apply BEM, HYDRALASTIC 836, or MEL-ROL LIQUID MEMBRANE 305 mm (12″) wide centered over the termination and while still wet, embed 305 mm (12″) wide DETAIL FABRIC into the HYDRALASTIC 836 or MEL-ROL LIQUID MEMBRANE and roll press into place. Ensure that DETAIL FABRIC is centered over the termination with 152.4 mm (6″) on each side of lap edge. Apply additional HYDRALASTIC 836 on all terminations of DETAIL FABRIC.
Additionally, the use of DETAIL TAPE H and DETAIL TAPE V from W. R. MEADOWS can be used in both horizontal and vertical end laps. View PRECON END LAP TAPING METHOD TECHNICAL BULLETIN for full information.
Penetrations and Protrusions … Detail around all horizontal and vertical penetrations using BEM, HYDRALASTIC 836, or MEL-ROL LIQUID MEMBRANE (two-component). Apply BEM, HYDRALASTIC 836, or MEL-ROL LIQUID MEMBRANE by forming a fillet around the pipe or protrusion, overlapping the fabric side of PRECON and the protrusion a minimum of 64 mm (2.5″). If the gap between the protrusion and the membrane is greater than 13 mm (½”), apply DETAIL FABRIC over uncured BEM, HYDRALASTIC 836, or MEL-ROL LIQUID MEMBRANE. All penetration and protrusion surfaces must be clean, rust-free, and sound prior to application of BEM, HYDRALASTIC 836, or MEL-ROL LIQUID MEMBRANE ( Application Video).
*MEL-ROL LIQUID MEMBRANE is a two-component material, not to be confused with MEL-ROL LM.
For horizontal applications involving a cluster of penetrations, consider the use of HYDRALASTIC 836. Prior to application of HYDRALASTIC 836, prepare the surfaces of the penetrations as above and provide a block out using 2′ x 4′ (.6 x 1.2 m) lumber or other in order to create a “pitch pan” area to receive HYDRALASTIC 836 ( Application Video).
Patching … Prior to pouring, inspect membrane for punctures or damage and repair as necessary with HYDRALASTIC 836 and/or DETAIL FABRIC. (BEM or MEL-ROL LIQUID MEMBRANE may be used in place of HYDRALASTIC 836.) In addition, ensure the membrane is free of standing water and has been cleaned of any deleterious materials that will affect the bond of the concrete to the membrane.
Underslab Application … Refer to ACI 302.1R: Chapter 4 – Site Preparation and Placing Environment for sub-grade preparation prior to PRECON placement.
LIMITATIONS/PRECAUTIONS
Concrete should be poured within 60 days of membrane installation. For installations below 4° C, contact W. R. MEADOWS technical services. When using bar supports, use those with a flat bottom. It is the responsibility of the licensed design professional of record to determine suitability of PRECON as the vapor mitigation barrier based on the published VOC permeance data per project and governmental regulations. It is suggested to follow good industry practices to install a passive (convertible to active) venting system or provide active venting above the mitigation barrier. Install PRECON in clean soil to avoid direct contact with liquid contaminants.
MASTERFORMAT NUMBER AND TITLE
07 13 00 – Sheet Waterproofing
TECHNICAL DATA
Property | Test Method | PRECON Results |
Thickness | ASTM D1000 | 1.85 mm (73 mil) |
Low Temp Flexibility | ASTM D1970, 180° @ -28.9° C | Pass |
Resistance to Hydrostatic Head | ASTM D5385-93 | 70 m (230’) |
Elongation, Polymeric Membrane | ASTM D412-06 | >400% |
Tensile Strength, Film | ASTM D882 | 63.4 MPa (9200 psi) |
Crack Cycling | ASTM C836 @ -26° C |
Pass |
Puncture Resistance | ASTM E154 | >934 N (>210 lb.) |
Peel Adhesion to Concrete | ASTM D903 | 1754 N/m (10 lb./in) |
Lap Peel Adhesion | ASTM D1876 | . 0.97 N/mm (5.60 lbf/in.) |
Moisture Vapour Transmission | ASTM E96B | 0.006 perms (0.0024 grains/ft.2/hr) (0.041 gram/m2/24 hr) |
Resistance to Fungi in Soil | GSA-PBS 07115 – 16 Weeks | No Effect |
Radon Transmittance (m/s) | k124/02/95 | <3.0 x 10-9 |
Radon Coefficient (m²/s) | k124/02/95 | <5.6 x 10-12 |
Gas Diffusion Coefficient (m²/s) | ASTM E96, Procedure B Modified (Solvent only – No Water) | >99% Purity Benzene 1.24 x 10-14 |
>99% Purity Toluene 8.24 x 10-15 |
||
>99% Purity Ethylbenzene 1.24 x 10-15 |
||
>99% Purity Trichloroethylene 1.90 x 10-14 | ||
>99% Purity Tetrachloroethylene (PCE/Perc) 3.21 x 10-15 |
||
>99% Purity Xylene 1.53 x 10-15 |
||
Methane Gas Transmission Rate, (mL/day·m²·atm) Cond. 24h @ 74±4°F and 50±10%RH; Gas = Methane (99.99% purity); Test @ 74±4°F: |
ASTM D1434 | 43 |
2024-08
Technical Literature
Data Sheets
Resources
- Sustainability Letter
- PRECON Installation Guidelines
- Corner Installation Guidelines
- Soil Nail Installation Guidelines
- Horizontal Application Installation Guidelines
- A Blindside Waterproofing Primer
- Radon Technical Bulletin
- CAN/CGSB 51.34-M86 for Underslab: Construction Canada
- End Lap Taping Method Tech Bulletin
- Cold Weather Application Tech Bulletin
- Shotcrete Technical Bulletin
- Create BIM Model
Specs & Details
Guide Specification
CAD Details
Videos
PRECON Video:
PRECON Animation
PRECON End Lap Application Video