BELLATRIX
Premium Concrete Enhancer
DESCRIPTION
BELLATRIX is formulated using dual-protection technology
combined with unique hybrid polymers, to offer the ultimate in
concrete protection. Proprietary, dual-action technology
provides the ultimate in both penetrating and film-forming
concrete protection. BELLATRIX offers environmentally
friendly, VOC-compliant protection, which provides increased
stain suspension and resistance against most contaminants found in
kitchens, retail food stores, restaurants, malls, garages,
warehouses, distribution centers, etc.
USES
While originally formulated to be used in conjunction with
hardened concrete floor systems, such as W. R. MEADOWS
LIQUI-HARD® and the INDUROSHINE™ polished concrete
system, BELLATRIX may also be utilized anywhere a clear,
high-gloss, dual-action concrete protection system is desired.
BELLATRIX is designed for use on previously sealed surfaces,
as well as surfaces that have been previously stained or dyed and
sealed. (Check compatibility with existing sealer prior to full
application.)
| FEATURES/BENEFITS |
- Permeable film allows moisture in cured concrete to evaporate.
- Seals surface and provides optimum gloss.
- Offers stain protection against many common stain-causing
contaminants.
- Produces a tough, uniform, breathable barrier for improved
durability.
- Dustproofs concrete
- Provides excellent blush resistance in damp environments.
- Applies easily and economically.
- VOC compliant.
- Protects the finish when used on polished concrete.
- For both indoor and outdoor use.
- Rejuvenates previously sealed or densified concrete.
|
PACKAGING
1 Gallon (3.79 Liter) Units/4 per Carton
5 Gallon (18.93 Liter) Pails
55 Gallon (208.20 Liter) Drums
COVERAGE*
500 – 1000 ft.²/gal. (12.27 – 24.54 m²/L)
Steel Troweled Concrete: 500-600 ft.² (12.27-14.73 m²)
Polished Concrete: 1000-1500 ft.² (24.54-36.81 m²)
*Coverage will vary due to
texture, porosity and condition of the concrete.
SHELF LIFE
One year in original, unopened container.
| SPECIFICATIONS |
- Complies with all current federal, state, and local
maximum allowable VOC requirements, including U.S.
EPA, SCAQMD, and OTC.
- Complies with Canada VOC Concentration Limits for
Architectural Coatings Regulations.
|
LEED INFORMATION
May help contribute to LEED credits: |
|
TECHNICAL DATA)**
The following results were obtained
under laboratory conditions:
Color (Wet): |
Milky White |
| Color (Dried): |
Clear/Transparent |
| Weight per Gallon, lb./gal: |
8.46 |
| pH: |
7.31 |
| VOC, g/L |
57.6 |
| Drying Time @ 73° F, 50%
RH |
1-2 hours*** |
|
Re-coat time: |
2-6 hours |
| Foot Traffic: |
4-6 hours |
| Wheel Traffic: |
6-12 hours |
| Adhesion to Concrete: |
Excellent |
| Ultraviolet light (UV) degradation tested to ASTM C
1315, 8.86: |
| Ultraviolet Resistance: |
Non-yellowing |
| Chalk Resistance: |
No chalking |
| Check/Peel Resistance: |
No deterioration |
**All technical data is typical information, and may vary due to test
methods, conditions and operator technique.
**Low concrete or air temperatures and/or high relative humidity will extend drying times. |
STAIN BLOCKING
BELLATRIX is formulated to provide a reasonable amount of
time for cleanup and removal of spills. Prior to that removal,
BELLATRIX will provide a barrier to the following
contaminants:
Evaluation Scale: E = Excellent, V = Very Good, G = Good, F = Fair, P = Poor |
| 24 Hour Stain Resistance |
| |
Untreated Concrete |
LIQUI-HARD and
BELLATRIX ** |
Used Motor Oil
Diesel Fuel
Ammonium Hydroxide
Phosphoric Acid
Pickle Juice
Salad Dressing
Grape Juice
BBQ Sauce
Ketchup
Mayonnaise
Hot Sauce |
P
F
G
P
P
P
P
F
F
G
P |
E
VG
E
P
VG
P
E
E
E
E
VG |
**Under laboratory conditions, using a two (2) coat application of BELLATRIX at 500 ft.²/gal. over concrete treated with LIQUI-HARD. To determine the optimum results, it is recommended that different dilution rates be tested in the field and evaluated for gloss and stain-resistance properties. |
APPLICATION
BELLATRIX is designed for existing concrete and should not be
used as a curing compound on freshly placed concrete. A small
test patch application is always recommended. The test patch
must be done using the same applicator (personnel), equipment,
surface preparation, application technique, and at the same
temperatures, relative humidity, airflow conditions, etc., that will
exist at the time of the full-scale BELLATRIX application.
Surface Preparation … The surface must be thoroughly clean,
dry and free of anything that will prevent BELLATRIX from
bonding properly with the concrete. This includes, but is not
limited to: bond breakers, release agents, coatings, oil, grease, unneutralized
acid stain, dirt, efflorescence, dust, etc.
Polished Concrete … BELLATRIX may be applied over
concrete that has been previously treated with a
densifier/hardener such as LIQUI-HARD and/or polished with a
system like INDUROSHINE. Concrete must be a minimum of
28 days old before polishing with INDUROSHINE. Allow a
minimum of 12 hours after a LIQUI-HARD treatment before
applying BELLATRIX. Best results are obtained if the surface is
burnished two hours after application of BELLATRIX. Use a
high speed burnisher with a 3000-grit or hogs hair pad. If
products or systems other than INDUROSHINE or LIQUIHARD
are used, a small test patch application is always
recommended.
Existing Concrete … BELLATRIX should be used full strength
on existing concrete (no dilution necessary). Concrete must be a
minimum of seven days old before applying BELLATRIX. The
concrete must be clean, dry and prepared, per Surface Preparation
instructions above.
Mixing … Any separation in the container must be re-dispersed
with gentle agitation prior to use. CAUTION: TO AVOID
FOAMING, DO NOT MIX EXCESSIVELY.
Application Method ... An industrial sprayer, such as a Chapin
1949, with a 5916 spray nozzle (or equivalent), delivering 1/10th of
a gallon per minute, is recommended. Application equipment must
be clean, dry and free of any previously used materials. After
initially spraying the product onto the surface, uniformly spread it
with a micro-fiber applicator. The micro-fiber pad should be prewetted
with BELLATRIX prior to use, and the product must not be
allowed to dry before spreading is complete. Optimum performance
is achieved with two (2) uniform coats. The second coat should be
applied at a 90° (right) angle to the first coat, only after the first
coat is thoroughly dry – typically six (6) hours after application,
depending on temperatures and conditions. NOTE: Keep surface
dry for a minimum of 48 hours after application; full stain blocking
ability will not be effective until 72 hours after final application.
Cleanup … While BELLATRIX is still wet, equipment can be
cleaned with soap and water. Once dried, the material can be
removed with a solvent, such as xylene or toluene.
PRECAUTIONS
KEEP FROM FREEZING. Do not use BELLATRIX as a curing
compound on freshly placed concrete. Do not use as a stand alone
product. Due to occasional uncontrollable variations in concrete
substrates, application error, etc., BELLATRIX may not block all
staining materials in every instance. BELLATRIX is formulated to
provide a reasonable amount of time for cleanup and removal of
spills. Do not apply when air, material or surface temperatures are
expected to fall below 40˚ F (4˚ C) within four hours of completed
application. DO NOT MIX WITH ANY OTHER PRODUCTS.
Stain resistance and gloss will vary with changes in dilution ratios,
coverage rates and with the nature of the substrate. A test area is
recommended to verify that the desired appearance and
performance is achieved with the intended use conditions.
HEALTH AND SAFETY
Direct contact may result in mild irritation. Inhalation may cause
irritation of the respiratory tract. Refer to Material Safety Data
Sheet for complete health and safety information.
This material last updated September 2010.


|