POINTING MASTIC
POINTING MASTIC
|
|
PACKAGING
5 Gallon (18.93 Liter) Pails
29 oz. (857.65 ml) Cartridges
COVERAGE
Approx. 200 lineal ft. (61m) per gallon (3.79 L), when used as
directed
FOR INDUSTRIAL USE ONLY
APPLICATION
Surface Preparation
All
surfaces to receive an application of POINTING MASTIC should be
dry, frost-free, clean and free of all contaminants.
Application Method For easy application, store at temperatures of 60°F (16°C) or higher before using. Material will be stiffer and more difficult to work with at cooler temperatures. POINTING MASTIC can be easily applied with a caulking gun or trowel. Apply only in areas that will not be covered with a waterproofing membrane. Apply and spread the material to a thickness of approximately 1/8" (3.18mm) in a strip 1 to 3 inches (25.4 to 76.2mm) wide.
A bead of POINTING MASTIC is applied to the top edge horizontal termination of the vaporproofing or waterproofing membranes on vertical walls.
The corner and footing on inside corners are finished with POINTING MASTIC in the center of the detail strip where the vertical wall and footing meet. The outside corner is finished with POINTING MASTIC in the lower center point where vertical wall and footing meet. POINTING MASTIC should also be applied at the laps around corners, extending 12 inches (30.48 cm) in each direction from the corner.
A bead of POINTING MASTIC should also be applied between membrane and clamping rings and at all terminations, drains and protrusions.
Clean up Tools can be cleaned with mineral spirits at the end of each workday. Follow manufacturer's precautions when using a solvent as a cleaner.
PRECAUTIONS
POINTING MASTIC VAPOR IS FLAMMABLE. Read and follow application
information and health and safety information on product label.
This material last updated October, 2005.



![]()
![]()