| 07 14 16 |
|
Related Content:
|
DESCRIPTION
MEL-ROL LM is a single-component, polymermodified,
cold-applied, water-based, liquid
waterproofing membrane ideal for below-grade
horizontal and vertical seamless waterproofing
applications. We have taken the same high quality
rubber polymers found in MEADOWS’ successful
MEL-ROL “peel and stick” membrane, and converted
them into a heavy-bodied, high solids, quick drying
liquid membrane.
With MEL-ROL LM, installation time is reduced, utilizing either a spray or roller application. A variety of different protection courses, insulation boards, or drainage boards can be embedded into the membrane to create a superior waterproofing system. With the application of PERMINATOR® vapor barrier over the membrane, a composite system can be created that has the combined advantages of both “peel and stick” and liquid-applied membranes.
USES
MEL-ROL LM can be used on new and remedial
waterproofing applications on concrete or masonry
block substrates. Since the formula is water-based,
MEL-ROL LM can also be used on both ICFs and“green concrete” applications.
| SPECIFICATIONS |
|
| LEED INFORMATION May help contribute to LEED credits: |
|
| FEATURES/BENEFITS |
|
PACKAGING
5 Gallon (18.93 Liter) Pails
55 Gallon (208.20 Liter) Drums*
*special order only
PHYSICAL PROPERTIES
| MEMBRANE | ||
| Color Solids Total Cure Time Service Temperature Application Temp Coverage |
Black 70% 16-24 hrs -20° F - 140° F (-29° C - 60° C) 40° F minimum 20-25 ft.²/gal. |
|
| Shore “00” Hardness Stability Elongation Water Absorption WVT |
Passes Exceeds 1500% 0.7% 0.03 Perms |
ASTM C 836 ASTM C 836 ASTM D 412 ASTM D 1970 ASTM E 96, B |
| Composite (55 Mil Membrane/10 Mil PERMINATOR) | ||
| Peel Adhesion Tensile Strength (Film) Elongation |
7 lb./in. (125
g/mm) 5000 PSI (36 MPa) 900% |
ASTM C 794 ASTM D 412 (Die C) ASTM D 412 (Die C) |
| Water Vapor Permeability Water Absorption Resistance to Hydrostatic Head Puncture Resistance |
0.02 Perms 0.1% 48 PSI 22 lbf. (98 N) |
ASTM E 96, B ASTM D 1970 ASTM D 751 ASTM D 4833 |
APPLICATION
Surface Preparation...
All surfaces must be clean
(free of all coatings and curing compounds), free of
frost, relatively smooth, and structurally sound. Patch
any bug holes, tie holes, large gaps, or cracks with
MEADOW-PATCH® 5 or MEADOW-PATCH 20 from W. R. MEADOWS. All loose laitance on the
substrates, such as dirt, dust, loose stones, and debris,
should be either swept or blown clean.
All shrinkage cracks less than 1/16" should be pretreated with a 60-mil coat of MEL-ROL LM 6" (15 cm) wide. All cracks greater then 1/16" should be taped with W. R. MEADOWS DETAIL STRIP prior to application of the membrane. For specific project recommendations, please contact W. R. MEADOWS technical services.
Mixing … MEL-ROL LM is designed to be used from the pail or drum with little or no mixing. However, if water appears on the surface, mix thoroughly with a low speed mechanical mixer prior to application.
Priming … To reduce blistering on concrete surfaces, a thin coat of MEL-ROL LM diluted with water may be required. (Approximate dilution ratio of MEL-ROL LM to water is between 4:1 and 5:1.) Thoroughly mix primer with a mechanical mixer. Prime the entire concrete surface to be waterproofed by spraying or rolling on a single coat at a coverage rate of 100-150 ft.²/gal. Allow primer to dry (approximately one hour, depending on temperature and conditions).
Detailing … After surface preparations are complete, detailing should be addressed. The desired thickness of membrane coverage is 120 mils for inside/outside corners and non-moving and hairline cracks, as well as around drains and penetrations.
Roller Application … MEL-ROL LM can be applied directly from the container using a ¾” nap roller. Apply in two coats, each 30 mils thick, allowing first coat to reach initial set prior to application of second coat.
Spray Application … MEL-ROL LM may be sprayed on vertical surfaces at a minimum coverage thickness of 60 mils wet (45 mils dry). A single coat may achieve desired coating thickness. However, if material slumps due to temperature or substrate conditions, two coats (30 mils wet) may be necessary. Apply the second coat after the first coat has dried (approximately one to two hours).
Spraying Equipment … MEL-ROL LM is most effectively applied by using the Graco HydraMax 350 or the Graco GH833 Big Rig. The Graco heavy-duty texture gun is recommended for use with the following tips: For best results, use the 0.051” (Graco GHD551) heavy-duty switch tip. For spraying of primer coat, a smaller orifice tip such as the 0.035” (Graco GHD635) can be used. Tips should be reversible types for easy clean out.
Horizontal Application … Contact your local W. R. MEADOWS sales office for specific recommendations.
Approximate Coverage … 20-25 ft.²/gal. @ 60 mils. Coverage dependant on substrate type, weather, and application conditions.
Thickness Control … Frequently inspect surface area with a wet mil gauge to ensure desired consistent thickness is achieved. Porous substrates or masonry block walls may require additional coats to obtain desired thickness.
Cleanup … Material should not be left in the pump, lines, or gun when finished spraying. CAUTION: Solvents must not come in contact with LM in the sprayer, as they will break the emulsion and plug up the entire sprayer system. After spraying, promptly flush water only (no soap) through the system until pump and hose are clear (approx. five gallons). Aromatic solvents, such as xylene or toluene (approx. two gallons), should be used for final flushing after water is flushed through the pump and lines.
Mineral spirits, paint thinner, gasoline, etc., must not be used to flush system. NOTE: Water must be flushed through the machine to remove any solvents prior to spraying of MEL-ROL LM.
Protection … Cover vertical applications with PROTECTION COURSE, MEL-DRAIN™ or 10 mil PERMINATOR from W. R. MEADOWS. Surfaces must be covered within 45 days.
Backfilling … Allow 24 hours for complete cure of membrane prior to backfilling.
SHELF LIFE (TYPICAL)
Six (6) months in unopened container. Store at
40° - 90° F.
PRECAUTIONS
Do not freeze. Do not apply MEL-ROL LM on
vertical projects if rainfall is forecast or imminent
within 12 hours. Do not apply MEL-ROL LM or
primer when air, material and surface
temperatures are expected to fall below 40° F
within four hours of completed application.
Sprayed urethane foams applied over MEL-ROL
LM can melt the membrane and cause
delamination and failure due to the exothermic
reaction that takes place after spraying the foam.
There foams should not be sprayed over MELROL
LM. The use of MEL-ROL LM does not
negate the need for relief of hydrostatic heads.
A complete drain tile system should be placed
around the exterior of footing and under slabs, as
required.
![]() |
![]() |
This material last updated March 2010.