| 03 39 23 |
|
Click
here for:
|

Resin-Based, Water-Based Concrete Curing
Compound
DESCRIPTION
The 1100-CLEAR series of water-based concrete
curing compounds is formulated from hydrocarbon
resins and may be used on interior, exterior,
vertical, and horizontal concrete surfaces. Once
applied, 1100-CLEAR forms a premium-grade
membrane that retains an optimum amount of water
in freshly placed concrete for complete hydration of
the cement. NOTE: After approximately four
weeks, the membrane begins to chemically break
down. The membrane will eventually dissipate
from the surface. This process usually takes another
3 - 5 weeks under normal traffic, exposure to UV,
and weathering conditions.
USES
The 1100-CLEAR series has been used on both
interior and exterior applications where paint,
resilient tile or resilient flooring may be applied
later. Because of the wide variety of coatings,
paints, adhesives, and toppings available, contact
the manufacturer of the flooring system or
subsequent coating or topping for application
approval over resin-based curing compounds. A
small test application is always recommended.
| FEATURES/BENEFITS |
|
| SPECIFICATIONS |
|
PACKAGING
5 Gallon (18.93 L) Pails
55 Gallon (208.20 L) Drums
TECHNICAL DATA
DRYING TIME: Typically dries in 1-2 hours,
depending on jobsite conditions (temperature,
wind, etc.) Restrict foot traffic for at least four
hours; 12 hours is preferable.
FLASH POINT: >210º F (99º C).
| LEED INFORMATION May help contribute to LEED credits: |
|
APPLICATION:
Preparation...Application equipment must be clean and free of all previously
used materials.
Mixing...For optimum performance, gentle mixing or agitation
is recommended. CAUTION: TO AVOID FOAMING, DO NOT MIX EXCESSIVELY. DO NOT THIN.
Application Method ...Apply in a uniform film to horizontal surfaces as soon as the surface water disappears and the surface will not be marred by walking workmen. On vertical surfaces, apply promptly after the forms are removed. 1100-CLEAR may be applied with a typical commercial hand or power sprayer. Use a Chapin 5797 or equivalent spray nozzle that produces a flow of 1/2 gal. (1.89 L) per minute under 40 psi (.276 MPa) of pressure.
Coverage...Approximately 200 ft.²/gal. (4.91
m²/L). Coverage rate may vary depending on
conditions (temperature, wind, etc.) at the jobsite, as well as the porosity and condition of the concrete.
Cleanup...Prior to drying, cleanup can be
accomplished with soap and water. Once dried,
use mineral spirits or other suitable petroleum
solvent.
PRECAUTIONS
KEEP FROM FREEZING. Do not apply if air
and/or concrete temperature is less than 40° F (4°
C). Improper or over-application may increase
the amount of time necessary for the film to
dissipate from the surface. SURFACE MAY
DISCOLOR AND/OR YELLOW DUE TO
OVER-APPLICATION. DO NOT MIX OR
DILUTE WITH ANY OTHER PRODUCTS OR
LIQUIDS. Do not apply paint, resilient flooring
or any other subsequent coatings or toppings
without first checking the specifications and
securing approval from the manufacturer of the
product being applied over 1100-CLEAR. A
small test application is always recommended. If
removal of 1100-CLEAR is necessary, use
ULTRITE® DEGREASER from W. R.
MEADOWS.
HEALTH AND SAFETY
Direct contact may result in mild irritation. Read
and follow all application, precaution, label, and
health and safety information prior to use. Refer to Material
Safety Data Sheet for complete health and safety information.
SHELF LIFE (TYPICAL)
One year in original, unopened container.
This material last updated May 2008.